Geotechnical Equipment
CPT system
A top-push wireline cone-penetration-testing system with 25 tonne push force, engineered to integrate with existing drilling systems.
The system interfaces with an existing sonic drill rig and jack-up barge, working through the barge’s moonpool. It is built around the client’s chosen hydraulic cylinders, with the structure, hydraulics, controls, wireline handling and safety designed and verified around them. CPT is deployed through the same rig used for sonic drilling, with repeatable installation and removal by barge crane.
How it works
Wireline CPT latches into the core barrel; a designated HPU and auxiliary circuit power the system; a wireline sheave is fitted on the drill mast and winch control sits on the CPT hydraulic panel. A “top hat” matched to the core-barrel ID lets the CPT pass through, and the system accommodates different casing sizes and casing stick-up. The existing equipment keeps its functionality.
| Type | Bespoke top-push wireline CPT, integrating with an existing sonic drill rig on a jack-up barge (moonpool-deployed) |
|---|---|
| Max push force | 25 tonne (operating pressure 162 bar) |
| Max pull-back | 10 tonne (operating pressure 32 bar) |
| Stroke | 1,500 mm minimum |
| Speeds | Push 2 cm/s ยท pull-back 1.5 m in 10.5 s |
| Casing | 10″ and 7″ deployed at deck level; accommodates varying sizes & stick-up |
| Finish | 3-coat epoxy paint |
| Design codes & tools | DNV-GL ST-0378, DNV-GL ST-N001; SolidWorks, SimSolid, DraftSight |